D Series Multistage centrifugal pump
Single-sorted, multi-stage, nodal centrifuge water pumps suitable for clean water without solid particles or liquids of similar nature.
The liquid is a multiple-stage sub-phase pump, which is selected to match the depth of the tank and installation.
The YDL type extends the multiple-phased pump segment into the liquid tank. The sample provides a YDL1 and YDL2 performance table, which can first be increased by flow, then check the tank, the depth of the fluid and the size of the connection.
Industrial tanks and equipment are accompanied by liquid transport.
Provides the liquid range, installation depth, pump installation port, medium and required pressure.
The sample contains performance tables, installation profiles and dimensions for different YDL specifications. The lower length changes with the configuration.
| Model | Flow rate Q (m³/h) | & H(m) | Power (kW) |
|---|---|---|---|
| YDL1-20 | 0.4 | 13 | 0.37 |
| YDL1-20 | 1 | 11.5 | 0.37 |
| YDL1-20 | 1.6 | 10 | 0.37 |
| YDL1-30 | 0.4 | 18 | 0.37 |
| YDL1-30 | 1 | 16.5 | 0.37 |
| YDL1-30 | 1.6 | 15 | 0.37 |
| YDL1-40 | 0.4 | 24 | 0.37 |
| YDL1-40 | 1 | 22.5 | 0.37 |
| YDL1-40 | 1.6 | 21 | 0.37 |
| YDL1-50 | 0.4 | 30 | 0.37 |
| YDL1-50 | 1 | 28.5 | 0.37 |
| YDL1-50 | 1.6 | 26 | 0.37 |
| YDL1-60 | 0.4 | 36 | 0.37 |
| YDL1-60 | 1 | 34 | 0.37 |
| YDL1-60 | 1.6 | 31 | 0.37 |
| YDL2-20 | 1 | 16 | 0.37 |
| YDL2-20 | 2 | 15 | 0.37 |
| YDL2-20 | 3 | 12.5 | 0.37 |
| YDL2-30 | 1 | 24 | 0.37 |
| YDL2-30 | 2 | 22 | 0.37 |
| YDL2-30 | 3 | 19 | 0.37 |
| YDL2-40 | 1 | 32.5 | 0.55 |
| YDL2-40 | 2 | 29.5 | 0.55 |
| YDL2-40 | 3 | 25.5 | 0.55 |
| YDL2-50 | 1 | 41 | 0.55 |
| YDL2-50 | 2 | 36.5 | 0.55 |
| YDL2-50 | 3 | 31 | 0.55 |
| YDL2-60 | 1 | 52 | 0.75 |
| YDL2-60 | 2 | 47 | 0.75 |
| YDL2-60 | 3 | 39 | 0.75 |
No matching model found, please check the input.
Tongda YDL sample page 3. Sample tests water temperature 20 °C using trio 380 V, 50 Hz.
Zoom in on the view
Zoom in on the view
Source: YDL Sub-Line Multi-stage Pumps